 60W Single Output Medical Type
Features :
4"x2" miniature size Universal AC input/Full range Low leakage current<200uA
RPS-60
series
Protections: Short circuit / Overload / Over voltage Cooling by free air convection UL60601-1/IEC60601-1/EN60601-1 medical safety approved UL60950-1/IEC60950-1/EN60950-1 ITE safety approved No load power consumption<0.75W Fixed switch frequency at 100KHz 3 years warranty
EN60601-1 IEC60601-1
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK LOAD(10sec.) OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER LOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE RPS-60-3.3 3.3V 10A 0 ~ 11A 33W
Note.4 36.3W
RPS-60-5 5V 10A 0 ~ 11A 50W 55W 80mVp-p 4.75 ~ 5.5V 2.0% 0.5% 1.0%
RPS-60-12 12V 5A 0 ~ 5.5A 60W 66W 120mVp-p 11.4 ~ 13.2V 2.0% 0.5% 1.0%
RPS-60-15 15V 4A 0 ~ 4.4A 60W 66W 150mVp-p 13.5 ~ 16.5V 2.0% 0.5% 1.0%
RPS-60-24 24V 2.5A 0 ~ 2.75A 60W 66W 240mVp-p 22.8 ~ 27.6V 1.0% 0.5% 1.0%
RPS-60-48 48V 1.25A 0 ~ 1.375A 60W 66W 300mVp-p 45.6 ~ 52.8V 1.0% 0.5% 1.0%
RIPPLE & NOISE (max.) Note.2 80mVp-p 3.1 ~ 3.6V 2.0% 0.5% 1.0%
500ms, 30ms/230VAC 50ms/230VAC 90 ~ 264VAC 47 ~ 63Hz 74% 1.8A/115VAC 79%
500ms, 30ms/115VAC at full load
13ms/115VAC at full load 127 ~ 370VDC 83% 30A/115VAC 84% 85% 86%
1 A/230VAC
COLD START 60A/230VAC
For earth <200uA / 264VAC, For patient <100uA/264VAC 115 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 3.8 ~ 5V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V Protection type : Shut down o/p voltage, re-power on to recover -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1, UL60601-1, TUV EN60601-1, IEC60601-1 approved
28.4 ~ 32.4V
55.2 ~ 64.8V
I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMC EMI CONDUCTION & RADIATION Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B
(Note 5)
HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS DIMENSION PACKING
NOTE
Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A 353.6Khrs min. MIL-HDBK-217F (25 101.6*50.8*29mm (L*W*H) 0.15Kg; 96pcs/15.4Kg/0.89CUFT )
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:RPS-60-SPEC 2008-03-25
60W Single Output Medical Type
Mechanical Specification
101.6 95.25
RPS-60
series
Unit:mm
3.175
3.175
SVR1
50.8
44.45
CN1
3 2 1
1 2 3 4 CN2 4- 3.3
3 max.
29
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No. 1 2 3 Assignment AC/N No Pin AC/L Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent
DC Output Connector (CN2) : JST B4P-VH or equivalent
Pin No. 1,2 3,4 Assignment +V -V Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent
Block Diagram
RECTIFIERS & FILTER RECTIFIERS & FILTER
fosc : 100KHz
POWER SWITCHING
I/P
EMI FILTER
+V -V
FG O.L.P. CONTROL
DETECTION CIRCUIT O.V.P.
Output Derating
Output Derating VS Input Voltage
Ta=25
100
100 90
80
80
60
70
LOAD (%)
LOAD (%)
0 10 20 30 40 50 60 65 70 (HORIZONTAL)
40
60 50 40
20
-20
90
95
100
115
120
140
160
180
200
220
240
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (VAC) 60Hz
File Name:RPS-60-SPEC 2008-03-25


▲Up To Search▲   

 
Price & Availability of RPS-60

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X